LSP02-2C Laboratorial Syringe Pump
Stroke of the drive unit:140mm
Flow range:0.831nl-150.5ml/min
No. of Syringes:2
Display:4.3 inch LCD touchscreen
Control:Touch Panel / External control signal
Motor:Stepper motor
- Main Functions and Features
- Selection Guide
- Service Guarantee
- Related Products
-
LSP02-2C is an infusion/withdrawal syringe pump . Metal spray appearance . Mainly used in Lab applications. The acceptable syringe specification is from 10 µL to 140 mL.
4.3 inch LCD touchscreen,Multiple work modes.
High precision and pulseless delivery, suitable for small liquid volume transfer and handling
Technical Specifications
Number of Channels:2
Display Setting:Display volume, flow rate, linear speed
Syringe Size:10µL – 140 mL
Power-off Memory:Storing the running parameters automatically
Dimensions (mm):280×250×140
Weights (Kg):4.5
Working Mode:Infusion / Withdraw
Linear Force:> 18Kg
Advance per Micro-step:1/16 Step (0.156µm)
Max. Step Rate:867 steps /sec
Min. Step Rate:1 step / 30 secs
Max. Linear Rate:130 mm/min
Min. Linear Rate:5µm/min
Setting Mode:4.3 inch LCD touchscreen
Display:4.3 inch LCD touchscreen
Power Supply:AC90-265V , 50Hz / 60Hz
Operation Condition:Temperature: 5℃ - 40℃, Relative humidity: 20% - 80% RH
Syringe Selection: The syringe can be selected in the manufacturer table which includes manufacturer, material and size or input the inner diameter of the syringe barrel directly
Easy to operate: 4.3 inch LCD touchscreen.
Working Mode: Infusion, withdrawal, infusion/withdrawal, withdrawal/infusion, continuous
Memory Function: 1. The parameters are saved in EEPROM. The parameters don't need to be reset when power returns after an interruption. 2.In flow rate mode, the pump remains running or stop according to the setting parameters when power returns
Protection Function: The pump will stall and give an alarm when the drive structure of the pump is blocked
Communication Function: Realize computer control through RS485 communication interface
External Control Function: Input/output control
Calibration Function: Acquire accurate volume through calibration
Syringe Protection: Adjust syringe rest to prevent syringe from damaging
-
Selection ideas
1. Confirm the demand flow (mL/min) and the number of pipelines to be transported
2. Confirm the usage scenario, which can be used directly, or it can be used with the device, controlled by RS485 or external signals
3. Parameter display, digital tube only shows the speed; LCD screen display flow, speed and other calibration parameters; The touchscreen displays flow, rotational speed, and other programming or configuration parameters
4. Liquid composition, affect the choice of hose, platinum vulcanized silicone tube recommended for conventional fluids, and imported hoses for corrosive fluids
Choosing a drive to consider
Flow - The higher the drive speed, the greater the flow rate, select the appropriate drive according to the reference flow
Control mode - fixed speed; Adjustable speed; Adjustable speed, support flow correction (to achieve precise control of flow); Adjustable speed, support flow distribution (quantitative distribution); Various forms such as external signal control are available
Parameter display - digital tube, LCD, touch screen
Protection - Depending on the environment in which it is used, the requirements for sealing, dustproof, and waterproof of the drive should be considered
Choosing a pump head should be considered
Flow - Select the appropriate pumphead by reference flow
Hose Change Frequency - With the exception of the OEM series, most pump heads are capable of quick hose changes
Number of channels suitable - When multi-channel requirements are required, multi-channel pumpheads can be selected or pumpheads can be connected in series
Chemical Resistance - Considers the effect on the pumphead material when fluid spills
Choosing a hose to consider
Flow - See the reference flow curve for the hose
Chemical resistance - choose the material of the hose
Fluid Temperature - Different materials have different temperature behaviors
Where a suction lift is required - a high-performance hose should be selected
Hose life - For different use conditions, hose life performance is different, such as BPT material hose is nearly 30 times more durable than domestic silicone tube
-
About the delivery date
Peristaltic pumps, syringe pumps, micro plunger pumps, silicone tubes and other products, most of which are in stock, can be delivered within 48 hours;
Filling machines, filling systems and other products are usually made to order, the inventory is relatively small, the delivery time is about 1 week, and a small part is in stock;
Common models of imported hose series products are in stock; Because the imported hose is affected by international logistics, under special circumstances, the delivery time is about 1~4 weeks;
Remarks: All peristaltic pump series products need 3 days of non-stop operation and aging before leaving the factory, so as to ensure a lower failure rate and let customers use it with confidence
About after-sales
One year warranty (except for consumables, improper use or man-made damage is not covered by the warranty)
Due to special circumstances such as traffic differences, use environment, personal reasons and other special circumstances due to selection or actual application, you can directly contact customer service for exchange without affecting secondary sales
About logistics (applicable in China)
Default Debang/SF delivery, please communicate with customer service and confirm special needs
-
LSP02-2YDual Channels Syringe Pump
Number of Channels:2Display Setting:Display volume, flow rate, linear speedSyringe Size:10&
LSP02-1C Laboratorial Syringe Pump
LSP02-1C is an infusion/withdrawal syringe pump . Mainly used in Lab applications. The a
LSP02-1Y Dual Channels Syringe Pump
Number of Channels:2Display Setting:Display volume, flow rate, linear speedSyringe Size:10&